Criticare nGenuity™ 8100 Monitor conscious sedation or post-procedure recovery monitoring

Criticare nGenuity™ 8100E Monitor Conscious Sedation or Post-Procedure Recovery Monitoring

Criticare nGenuity 8100EP1  with CO2, Printer

The Criticare nGenuity 8100E Series patient monitor is ideal for monitoring pulse oximetry (SpO2), non-invasive blood pressure, heart rate, temperature, respiration and ECG during conscious sedation or post-procedure recovery. It comes with a full compatibility with popular Electronic Medical Records (EMR) systems makes it easy for any facility or office to transfer patient data. Lightweight design and has a carry handle, the nGenuity 8100E monitor also can be wall mounted or attached to a rolling stand for increase any medical setting. For portability, a sealed battery inside the unit can be recharged with a standard AC plug.

Features:

      • Monitors pulse oximetry (SpO2), non-invasive blood pressure, heart rate, temperature, respiration and ECG.
      • Easy to read 10.4 inch color display with minitrends display of condensed tabular vital signs data.
      • Large, membrane style keys • Simplified user interface
      • Compact and lightweight design
      • Compatible with popular Electronic Medical Records (EMR) systems
      • Proprietary ComfortCuff NIBP by Criticare which measures on inflation for a faster, more comfortable reading.
      • Monitors End-tidal CO2 and inspired CO2 accurately at high respiration rates.
      • Weight: 14 lbs; 6.4 kg • Dimensions: 11 in (H) x 13 in (W) x 10.3 (D)

    • Can be carried, wall mounted or quickly attached to a rolling stand.

CAPNOGRAPHY (CO2)

CAPNOGRAPHY (CO2)

CAPNOGRAPHY (CO2)

Units:

mmHg; kPa; Torr; Percent

Method:

Non-dispersive infrared; autocalibrating

N2O Compensation:

Manual (On/Off, user selectable

Range:

0 to 99 mmHg; 0 to 12.5%;

Flow, Sample Rate:

Sidestream; 200 ml/min

Accuracy:

 ±2 mmHg, ±0.3 volume %, ±0.3kPa, or ±2 Torr at 200 ml/min and respiratory rate equal or less than 120 bpm

Rise Time:

170 ms (10 to 90%) at 200 ml/min


ECG 0r CG or EKG

electrocardiogram ECG />
<img src= ECG Wrist Clips

ECG

Number of Leads:

3 – or 5 Lead

Lead View:

User-selectable; I, II, III, aVR, aVL, aVF, V (5-Lead);  I, II, or III (3-Lead)

Gain Selection:

x0.5, x1, x2, and x4

Frequency Response:

Diagnostic: 0.05 to 100 Hz (-3dB);

Monitor:

0.5 to 40 Hz (-3dB);

ST:

0.05 to 40 Hz (-3dB

Electrosurgery Protection:

Yes

Defibrillator Protection:

Yes

Pacer Detection/Rejection:

Yes

ST Accuracy:

 ±0.2 mm or ±5% of reading, whichever is greater, over heart range of 30 to 120 bpm

ST Range:

 -6.0 to 6.0 mm

 

 


Non-Invasive Blood Pressure (NIBP)

Heart Rate Plus

NIBP

Technique:

Oscillometric measure upon inflation

Inflation Range:

Adult/Pediatric: 0 to 300 mmHg: Neonate: 0 to 150 mmHg

Measurement Cycle:

< 40 sec. typical; standard adult cuff

Auto. Measurement:

2, 3, 5, 10, 15, 30 min; 1, 2, 4 hour intervals

STAT Mode:

 5 minutes

of consecutive readings

Maximum Cuff Pressure:

 Adult/Pediatric:

300 mmHg; Neonate: 150 mmHg

Resolution:

1 mmHG

Transducer Accuracy:

±2 mmHg or ±2% of reading, whichever is greater, over full range

Clinical Accuracy:

Complies with AAMI


PULSE OXIMETRY

Criticare Finger Sensor

Range:

 1% to 99%

Resolution:

1%

Accuracy:

70% to 99% range: ±2%; 50% to 69% range: ±3%; < 50%: unspecified

Method:

Dual wavelength LED

 

HEART RATE (PULSE)

Source:

User selectable: Smart, ECG, Pleth, NIBP

Range:

20 to 300 bpm (ECG, Pleth); 30 to 240 bpm (NIBP)

Accuracy:

±1 bpm or ±1% (ECG) whichever is greater

 

TEMPERATURE

Channels:

1

Probe:

YSI-400 and YSI-700 Series

Range, Accuracy:

68° to 113°F (20° to 45°C): ±0.1°C

Display Resolution:

0.1°C

 

RESPIRATION

Rate

6 to 150 bpm (ECG); 2 to 120 (CO2)

Resolution:

1 breath/min

Accuracy:

±1 breath/min

Source:

User selectable: Smart, CO2, ECG-TTI